I.          Technical Director

            Kelley J. Lapping

            620-757-6555

 

II.         Seating

A.         Main Floor -  Theater style 310 seats

            Main can be set with tables and chairs for other events. This will have fewer seats.

B.         Balcony - Radial 516 seats

 

III.        Stage

A.         Width of proscenium   37’-7”

B.         Height of proscenium  21’-8”

C.        Plaster line to rear wall   23’-4”

D.         Width rail to stairs  48’-6”

E.          Wing space stage right   none

F.          Wing space stage left  9’-6”

G.         Stage floor to grid   40’3”

H.         Proscenium thickness   2’-6”

I.           Stage thrust arch size to proscenium: Stage left  2’-6”

                                                                              Center  8”-0”

                                                                              Stage right  2’-6”

J.         Stage height from main floor   2’-8”

 

IV.        Load-in/out

A.         Loading door upstage left off of alley. Two step down to stage.

B.         Door size  7’-11” x 7’-11”

V.         Fly system

A.         Manual line sets  11

B.         Motorized electrics  3

C.         Rail is located stage right

VI.        Power

             A.          Location upstage left

             B.          Lights     400 amps  3 phase 120/208

                          Sound    200 amps  3 phase 120/208

VII.       Lighting

            A.   Fixtures:     24 - Leviton 19 degree lekos

                                       8 - Leviton 36 degree lekos

                                     32 -  Altman 6” fresnels

                                       7 -  Altman FC-1 single cell cyc

            B.   Followspot:  1 - Lycain 1209 Midget HP

            C.   Console: Innovator 48/96 with monitor

            D.   Dimmers:    138 - 2.4Kw Leviton dimmers

VIII.     Sound

            A. See attachments

IX.       Drapes

            A.  Full main

            B.   Legs  3 sets

            C.   Borders  3

X.         Dressing Rooms

             A.  2 large dressing with bathrooms and showers

             B.   2 star dressing rooms

              C.  1 washer and 1 dryer

              D.   Small area for green room

              E.    All of the above located under the stage

XI.         Other Numbers

              A.  Distance from proscenium to mix position house left  41’-0”

              B.   Distance from followspot to center stage  83’-8”

              C.   Intercom:  see attachment

              D.    Line plot:

                     1            Main drape            1’-4”

                     2            1st Electric               4’-7”

                     3            Spare                      6’-0”

                     4            Spare                      6’-9”

                     5            Screen                    7’-6”

                     6            2nd Electric             8’-10”

                     7            Spare                     10’-6”

                     8            Spare                     11’-3”

                     9            Spare                     15’-0”

                   10            Spare                     15’-9”

                   11            3rd Electric             17’-9”

                   12             Spare                    19’-6”

                   13             Spare                    20’-3”

                   14             Spare                    21’-0”